High-temperature Resistant Dental Resin

High-temperature Resistant Dental Resin

Details
When removable dentures are cast, does the model deform under high temperature? AIDENT High-Temperature Resistant Dental Resin TF is the professional solution. It withstands 120°C for direct flasking, delivers only 0.4% warpage, and allows fast, clean demolding. From printing to flasking, the entire process becomes faster and more reliable — no more deformation, no more rework.
Category
Dental 3D Resin
 
Send Inquiry
Description
Technical Parameters

Shenzhen Aident Technology Co., Ltd. is one of the leading manufacturers and suppliers of high-temperature resistant dental resin in China, featured by quality products and good service. Please rest assured to wholesale customized high-temperature resistant dental resin from our factory. For OEM/ODM service, contact us now.

 

High-Temperature Resistant Dental Resin TF – 120°C Heat Resistant for Denture Flasking

sPqKayGXBi6Zcogi.webp

Why Choose AIDENT High-Temperature Resistant Dental Resin TF

AIDENT High-Temperature Resistant Dental Resin TF is specially engineered for dental laboratories that need stable models under high-temperature flasking conditions. Unlike standard model resins that soften or warp, TF maintains dimensional accuracy at 120°C, enabling direct casting while preserving fine tissue surface details.

 

Shenzhen Aident Technology Co., Ltd. is a leading manufacturer and supplier of high-temperature resistant dental resin in China. We offer high-quality products, reliable service, and full OEM/ODM customization. Contact us for wholesale or private-label solutions.

tire change & repair

120°C High Temperature Resistance

Withstands direct casting at 120°C without permanent deformation. The model softens slightly under heat but returns to original shape after cooling, ensuring perfect replication of edges and tissue surfaces. No secondary adjustment of the denture base is required.

0.4% Ultra-Low Warpage

Full-arch models maintain excellent accuracy with warpage rate below 0.4%. Better base-to-mucosa adhesion reduces patient foreign-body sensation and saves approximately 30% of chairside adjustment time.

Water Absorption < 0.5%

Extremely low water absorption prevents deformation during steam cleaning. Models can be reused for multiple casting batches (typically 2–3 times), reducing material consumption and production time.

Easy & Fast Demolding

Low demolding resistance allows the denture base to separate cleanly with minimal force. Casting cycle time can be reduced from about 2 hours to 1 hour per batch, significantly improving laboratory throughput.

VqR5Ff0c83YSbitS.webp
OQkxKlNKhlpinlXG.webp

Application Scenarios

  • High-temperature casting of removable denture models
  • Accurate flasking and base flipping of denture bases
  • Orthodontic research and study models requiring thermal stability
  • Multi-batch reusable models for efficient laboratory production

How to Achieve Best Results

  • Print with recommended exposure settings for your LCD/DLP printer (385–405 nm).
  • Properly post-cure the model according to standard dental resin procedures.
  • Use for direct flasking at temperatures up to 120°C.
  • After cooling, demold gently - the low adhesion makes separation quick and clean.
  • Clean with steam if needed; low water absorption keeps the model stable for reuse.

For detailed printing parameters and post-processing recommendations, please contact our technical team or request the full TDS.

DsQM3mvxIN7a5PWb.webp

 

 

Technical Parameters

 

 

Parameter Value Standard
Model TF -
Color Pink -
Hardness Shore D 88 ASTM D2240
Flexural Strength 76.2 – 81.5 MPa ASTM D790
Water Absorption < 0.5% -
Warpage Rate < 0.4% -
Heat Resistance 120°C (direct flasking) -
Recommended Printers LCD / DLP (385–405 nm) -
Typical Applications Removable denture flasking, orthodontic models -

 

 

FAQ

 

 

Q: Can the model be reused after casting at high temperature?

A: Yes. The resin maintains Shore D 88 hardness after cooling from 120°C casting. Models can typically be reused 2–3 times without significant loss of accuracy.

Q: Will tissue surface details be preserved after casting?

A: Yes. The tissue surface details remain precise. The denture base replicates the model accurately, reducing or eliminating the need for manual polishing of the tissue surface and improving overall fit.

Q: What is the maximum recommended casting temperature?

A: The resin is designed for reliable performance at 120°C. Higher temperatures (e.g., 150°C) are not recommended for optimal dimensional stability and reuse life.

Q: Is this resin compatible with common dental 3D printers?

A: Yes. It is suitable for most LCD and DLP printers operating at 385–405 nm. Contact us for validated settings for popular models.
Q: Do you offer OEM/ODM or private-label service?
A: Absolutely. As a professional manufacturer, we support customized packaging, labeling, and formulation adjustments. Please contact us for details.

Q: How does TF differ from standard dental model resin?

A: Standard model resins often deform or warp under high-temperature flasking. TF is specifically formulated for 120°C resistance, ultra-low warpage (0.4%), and easy demolding, making it ideal for removable denture production.

product-800-500

Ready to improve your denture flasking process?

 

Get stable 120°C performance, lower warpage, and faster production with AIDENT High-Temperature Resistant Dental Resin TF.

 

Contact now

 

 

 

Hot Tags: high-temperature resistant dental resin, China high-temperature resistant dental resin manufacturers, suppliers, factory, 3D Resin Printer Resin, 3D Printing Dental Model Resin, 3d dental model, Dental Model UV 3D Resin, High precision Model Printing Materials, dental 3d resin

Send Inquiry
Contact usif have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!