The accuracy of a modern intraoral scanner is typically expressed as ≤10 μm for high-performance models under controlled conditions. In clinical practice, single-unit and short-span scans commonly achieve 10–50 μm, while full-arch scans from leading devices stay under 100 μm - well within accepted thresholds for fixed restorations. The Aident AI-30 Intraoral Scanner is specified at ≤10 μm full-arch accuracy, combining structured-light technology with real-time true-color capture to support crowns, bridges, implants, and orthodontic workflows.
Trueness vs Precision – The Two Metrics That Matter
Accuracy is not a single number. It consists of two distinct measurements:
| Metric | Definition | What It Means Clinically |
|---|---|---|
| Trueness | How closely the digital model matches the real geometry | Determines marginal fit and occlusion accuracy |
| Precision | How repeatable the scans are when the same area is rescanned | Ensures consistency between operator and appointment |
Both are measured in micrometers (μm). Lower values are better. A scanner can show excellent single-tooth trueness yet accumulate error across a full arch due to stitching.
Typical Accuracy Ranges by Application (2025–2026 Data)
| Application | Typical Trueness Range | Clinical Acceptability |
|---|---|---|
| Single crown / veneer | 10–40 μm | Excellent marginal fit |
| Short-span bridge (3–4 units) | 20–60 μm | High first-fit rates |
| Full-arch dentate | 40–100 μm | Acceptable for most fixed work |
| Full-arch implant | Higher variability | Technique & scan-body dependent |
Recent in-vivo studies show top scanners (Primescan series, Medit i900, TRIOS 5) delivering full-arch trueness in the 41–61 μm range, with all modern systems remaining under the commonly cited 100–120 μm clinical threshold for fixed prosthodontics.
Key Factors That Affect Real-World Accuracy
Scan span – Error accumulates with distance. Single units are far more forgiving than full arches.
Moisture and soft tissue – Saliva and blood reduce optical performance; isolation and anti-fog technology matter.
Depth of field – Scanners with 20–25 mm depth of field capture subgingival margins more reliably in one pass.
Operator technique & strategy – Consistent paths and proper angulation reduce stitching error.
Hardware + software – Structured light density, frame rate, and intelligent stitching algorithms determine final mesh quality.
Testing conditions – Manufacturer specs are often measured on ideal models; clinical results include patient movement and saliva.
Manufacturer Spec vs Clinical Performance
| Scanner Type | Typical Manufacturer Claim | Realistic Full-Arch Clinical Range | Notes |
|---|---|---|---|
| High-end (Primescan, TRIOS) | Premium accuracy | 40–70 μm | Strong published data |
| Open mid-to-high (Medit, Aoralscan, Aident) | ≤10 μm | 40–80 μm range in studies | Excellent value + openness |
| Entry-level | 20–50 μm | Higher variability | Suitable for simpler cases |
The gap between a ≤10 μm laboratory specification and clinical full-arch results is normal and expected. What matters is whether the scanner consistently stays inside the clinically acceptable window and delivers high first-fit rates.
Why ≤10 μm Accuracy Matters for Clinics and Labs
Better marginal integrity → fewer adjustments and remakes
Reliable occlusal relationships → reduced chairside time
Consistent data for labs → higher technician confidence
Support for same-day workflows when paired with open CAD and 3D printing
After working with distributors across Europe, the Middle East, and Asia, the most common feedback is that long-term success depends less on the absolute lowest micron number and more on day-to-day consistency, ease of use, and after-sales support.
How the Aident AI-30 Delivers Reliable Accuracy
The Aident AI-30 Intraoral Scanner is engineered by Shenzhen Aident Technology Co., Ltd. with the following verified specifications:
Accuracy (full arch): ≤10 μm
Weight: 156–198 g
Scanning speed: ≥30 frames per second
Depth of field: 0–25 mm
Powder-free true-color scanning with intelligent anti-fog heating
Open export: STL / PLY / OBJ
Software: AIDENT lScan with lifetime free upgrades
These features combine to produce dense, clean point clouds and clear preparation margins, supporting crowns, bridges, implants, and orthodontic applications within a fully open Scan → Design → Print workflow.
Need distributor pricing or a clinical demo of the AI-30?
Contact the Aident factory team for current specifications, test data, and OEM options.
FAQ
What is a good accuracy number for an intraoral scanner?
For single units and short bridges, ≤20–30 μm is excellent. For full-arch work, staying under 100 μm is widely considered clinically acceptable.
Is manufacturer "10 μm" the same as clinical full-arch accuracy?
No. The 10 μm figure is typically measured under controlled conditions. Real full-arch performance is higher but still clinical for modern scanners.
Does higher accuracy always mean better restorations?
Not by itself. Consistency, scanning strategy, moisture control, and lab communication often have a larger impact on final fit than a few microns difference between premium devices.
Can the Aident AI-30 be used for implant and full-arch cases?
Yes. Its ≤10 μm specification, 0–25 mm depth of field, and open file formats make it suitable for implant planning, surgical guides, and full-arch restorative work when proper technique is applied.
How does accuracy compare between Chinese and European/Korean scanners?
Top-tier European and Korean systems often lead published in-vivo rankings. Well-engineered open systems from China (including Aident) deliver clinically comparable results at a more accessible price point with no mandatory subscription fees.
Ready to Evaluate Real Accuracy in Your Clinic?
Request:
✓ Detailed AI-30 accuracy specifications and test reports
✓ Distributor price list
✓ OEM / ODM information
✓ Product demo or sample scan data
Contact Shenzhen Aident Technology Co., Ltd. today through the inquiry form on aident3d.com or via WhatsApp.

